Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clinics (Sao Paulo) ; 71(2): 82-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26934237

RESUMO

OBJECTIVE: This work aimed to evaluate and correlate symptoms, biochemical blood test results and single nucleotide polymorphisms for lactose intolerance diagnosis. METHOD: A cross-sectional study was conducted in Fortaleza, Ceará, Brazil, with a total of 119 patients, 54 of whom were lactose intolerant. Clinical evaluation and biochemical blood tests were conducted after lactose ingestion and blood samples were collected for genotyping evaluation. In particular, the single nucleotide polymorphisms C>T-13910 and G>A-22018 were analyzed by restriction fragment length polymorphism/polymerase chain reaction and validated by DNA sequencing. RESULTS: Lactose-intolerant patients presented with more symptoms of flatulence (81.4%), bloating (68.5%), borborygmus (59.3%) and diarrhea (46.3%) compared with non-lactose-intolerant patients (p<0.05). We observed a significant association between the presence of the alleles T-13910 and A-22018 and the lactose-tolerant phenotype (p<0.05). After evaluation of the biochemical blood test results for lactose, we found that the most effective cutoff for glucose levels obtained for lactose malabsorbers was <15 mg/dL, presenting an area under the receiver operating characteristic curve greater than 80.3%, with satisfactory values for sensitivity and specificity. CONCLUSIONS: These data corroborate the association of these single nucleotide polymorphisms (C>T-13910 and G>A-22018) with lactose tolerance in this population and suggest clinical management for patients with lactose intolerance that considers single nucleotide polymorphism detection and a change in the biochemical blood test cutoff from <25 mg/dL to <15 mg/dL.


Assuntos
Intolerância à Lactose/diagnóstico , Intolerância à Lactose/genética , Polimorfismo de Nucleotídeo Único , Adolescente , Adulto , Idoso , Alelos , Área Sob a Curva , Glicemia/análise , Brasil/etnologia , Estudos Transversais , Feminino , Genótipo , Humanos , Lactose/farmacocinética , Intolerância à Lactose/sangue , Masculino , Pessoa de Meia-Idade , Fenótipo , Polimorfismo de Fragmento de Restrição , Sensibilidade e Especificidade , Adulto Jovem
2.
Clinics ; 71(2): 82-89, Feb. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-774528

RESUMO

OBJECTIVE: This work aimed to evaluate and correlate symptoms, biochemical blood test results and single nucleotide polymorphisms for lactose intolerance diagnosis. METHOD: A cross-sectional study was conducted in Fortaleza, Ceará, Brazil, with a total of 119 patients, 54 of whom were lactose intolerant. Clinical evaluation and biochemical blood tests were conducted after lactose ingestion and blood samples were collected for genotyping evaluation. In particular, the single nucleotide polymorphisms C>T-13910 and G>A-22018 were analyzed by restriction fragment length polymorphism/polymerase chain reaction and validated by DNA sequencing. RESULTS: Lactose-intolerant patients presented with more symptoms of flatulence (81.4%), bloating (68.5%), borborygmus (59.3%) and diarrhea (46.3%) compared with non-lactose-intolerant patients (p<0.05). We observed a significant association between the presence of the alleles T-13910 and A-22018 and the lactose-tolerant phenotype (p<0.05). After evaluation of the biochemical blood test results for lactose, we found that the most effective cutoff for glucose levels obtained for lactose malabsorbers was <15 mg/dL, presenting an area under the receiver operating characteristic curve greater than 80.3%, with satisfactory values for sensitivity and specificity. CONCLUSIONS: These data corroborate the association of these single nucleotide polymorphisms (C>T-13910 and G>A-22018) with lactose tolerance in this population and suggest clinical management for patients with lactose intolerance that considers single nucleotide polymorphism detection and a change in the biochemical blood test cutoff from <25 mg/dL to <15 mg/dL.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Intolerância à Lactose/diagnóstico , Intolerância à Lactose/genética , Polimorfismo de Nucleotídeo Único , Alelos , Área Sob a Curva , Glicemia/análise , Brasil/etnologia , Estudos Transversais , Genótipo , Intolerância à Lactose/sangue , Lactose/farmacocinética , Fenótipo , Polimorfismo de Fragmento de Restrição , Sensibilidade e Especificidade
3.
Rev Esc Enferm USP ; 45(1): 153-60, 2011 Mar.
Artigo em Português | MEDLINE | ID: mdl-21445502

RESUMO

This study performed a bacteriological analysis of the liquid soap in dispensers that health professionals use for hand washing. This exploratory, cross-sectional study was developed at the hospitalization units of a medium-sized hospital in Fortaleza, Ceará, Brazil. Data were collected between May and July 2007. Fifty-nine liquid soap dispensers were analyzed, of which 33 contained the following microorganisms: Burkholderia cepacia (14), Pseudomonas putidas (9), Pseudomonas aeruginosa (3), Klebsiella pneumoniae (3), Enterobacter clocae (2), and Pseudomonas luteola (2). The units with the largest number of contaminated samples were the surgical (n=7) and the dermatological clinics (n=4). Contamination was also found in an original flask of the same lot of liquid soap used to fill up the dispensers. In conclusion, there is a need to regulate and control the quality of these products in the production lines as well as during use in hospital services, mainly because they are used to prevent hospital infection.


Assuntos
Bactérias/isolamento & purificação , Fômites/microbiologia , Sabões , Estudos Transversais , Unidades Hospitalares , Hospitais
4.
Rev. Esc. Enferm. USP ; 45(1): 153-160, mar. 2011. tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: lil-579747

RESUMO

O estudo realizou a análise bacteriológica de sabões líquidos utilizados para lavagem das mãos dos profissionais de saúde. Trata-se de estudo exploratório transversal, desenvolvido nas unidades de internação de hospital de médio porte em Fortaleza/CE. Os dados foram colhidos no período de maio a julho de 2007. Do total de 59 frascos com sabão líquido, 33 continham os seguintes microorganismos: Burkholderia cepacia (n=14), Pseudomonas putidas (9), Pseudomonas aeruginosa (3), Klebsiella pneumoniae (3), Enterobacter cloacae (2), Pseudomonas luteola (2). As unidades com maior número de amostras contaminadas foram a clínica cirúrgica (n=7) e a clínica dermatológica (n=4). A contaminação também foi verificada em frasco original do mesmo lote de sabão líquido usado para abastecer as saboneteiras. Podemos concluir ser necessário disciplinar e controlar a qualidade desses produtos nas linhas de produção tanto quanto nas fases de uso nos serviços de saúde, sobretudo porque sua utilidade se presta à prevenção de infecção hospitalar.


This study performed a bacteriological analysis of the liquid soap in dispensers that health professionals use for hand washing. This exploratory, cross-sectional study was developed at the hospitalization units of a medium-sized hospital in Fortaleza, Ceará, Brazil. Data were collected between May and July 2007. Fifty-nine liquid soap dispensers were analyzed, of which 33 contained the following microorganisms: Burkholderia cepacia (14), Pseudomonas putidas (9), Pseudomonas aeruginosa (3), Klebsiella pneumoniae (3), Enterobacter clocae (2), and Pseudomonas luteola (2). The units with the largest number of contaminated samples were the surgical (n=7) and the dermatological clinics (n=4). Contamination was also found in an original flask of the same lot of liquid soap used to fill up the dispensers. In conclusion, there is a need to regulate and control the quality of these products in the production lines as well as during use in hospital services, mainly because they are used to prevent hospital infection.


El estudio realizó el análisis bacteriológico de jabones líquidos utilizados para lavado de manos de los profesionales de salud. Se trata de un estudio exploratorio transversal, desarrollado en las unidades de internación de hospital mediano en Fortaleza, Ceará, Brasil. Los datos fueron recolectados en el período de mayo a julio de 2007. Del total de 59 frascos con jabón líquido, 33 contenían los siguientes microorganismos: Burkholderia cepacia (n=14), Pseudomonas putidas (9), Pseudomonas aeruginosa (3), Klebsiella pneumoniae (3), Enterobacter cloacae (2), Pseudomonas luteola (2). Las unidades con mayor número de muestras contaminadas fueron la de clínica quirúrgica (n=7) y la clínica dermatológica (n=4). Se verificó también contaminación en frasco original del mismo lote de jabón líquido usado para abastecer las jaboneras. Podemos concluir en que es necesario disciplinar y controlar la calidad de estos productos en las líneas de producción, tanto como en las fases de uso en los servicios de salud, sobre todo porque su utilidad apunta a la prevención de infecciones hospitalarias.


Assuntos
Bactérias/isolamento & purificação , Fômites/microbiologia , Sabões , Estudos Transversais , Unidades Hospitalares , Hospitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...